ART00006073_Exhibit CL_104 - Chweechen Lim (Artelia).pdf - Email exchange between AUK, Leadbitter and the TMO.pdf [pdf]
… Furthar Package Quotes - see below i tem 10. 9. Compl iant Cladding Breakdown -• provided by CC in emaii of IS/C2. 10, … for any further response e t c l l . i . Further Cladding Quotes •- see above Item 10. l i b . Value … fur ther informat ion you expect to be able to get on the cladding costs. Yau were going to provide this last week - …
Published on:
BRE00003276_BRE report (No. 220867) following BS8414 Part 1_ 2002 Test on an Insulated Phenolic Rainscreen system (Kooltherm K15) belonging to Kingspan_0.pdf [pdf]
… profiles 3.3 Post test damage report 3.3.1 Cement board overcladding 3.3.2 Insulation Layer 4 Reference Test report … of assessing the behaviour of non-load bearing external cladding systems, rainscreen overcladding systems and external wall insulation systems when …
Published on:
ART00008243_Exhibit AD_250 - Email chain between AUK, Studio E and TMO dd. 26 February 2013 - 15 March 2013.pdf [pdf]
Published on:
ART00008280_Exhibit AD_224 - Email chain between AUK, Leadbitter and TMO dd. 30 January 2013 - 26 February 2013.pdf [pdf]
… Further M&E Package Quotes- see below Item 10. 9. Compliant Cladding Breakdown ····provided by CC in email of 18/02 . … anticipated for any further response etc . .lla. Further Cladding Quotes- see above Item 10. llb. Value Engineering- … further information you expect to be able to get on the cladding costs. You were going to provide this last week- …
Published on:
BRE00003276_BRE report (No. 220867) following BS8414 Part 1_ 2002 Test on an Insulated Phenolic Rainscreen system (Kooltherm K15) belonging to Kingspan.pdf [pdf]
… profiles 3.3 Post test damage report 3.3.1 Cement board overcladding 3.3.2 Insulation Layer 4 Reference Test report … of assessing the behaviour of non-load bearing external cladding systems, rainscreen overcladding systems and external wall insulation systems when …
Published on:
BRE00005797_BRE BS 8414-1_2002 test on Dryvit UK Limited Outsulation system with 300 mm EPS insulation Test Report Number 241823 - 1_1.pdf [pdf]
… of assessing the behaviour of non-load bearing external cladding systems, rainscreen overcladding systems and external wall insulation systems when … an opening such as a window aperture that exposes the cladding to the effects of external flames. The …
Published on:
CEL00001182_Update on accreditation of FR5000 for use above 18m.pdf [pdf]
… . BS 841 4: 1 - Test method for non-loadbearing external cladding systems applied to the face of the bui ld ing. Part … BS 8414:2 - Test method for non-loadbearing external cladding systems f ixed to and supported by a structural steel frame. Part 2 is concerned with rainscreen cladding on steel frame constructions. Predominantly new …
Published on:
BRE00047589_CWCT Technical Conference - Fire Testing Expericences handout.pdf [pdf]
… the potential risk of fire spread in buildings via External Cladding was held by the Envilonment Sub-commitiee of the … BRE LPCB Dijon, France-2010 LPCB Recent High Rise External Cladding Fires LPCB LPCB VertJcalFJreSpread bre LPCB LPCB … Safety ) Guidance LPCB LPCB LPCB LPCB Approval of External Cladding Systems LPCB LPCB Thank you BRE Copyright 2014 7 …
Published on:
BRE00047584_Exhibit SC_5_1 - Email Sarah Colwell to Tony Baker re_ ADB Clause 12.6, 12.7.pdf [pdf]
… and specifically relating to certain build ups of external cladding systems and whether these require testing an … to BS 8414 and BR lg5 respectively, as follows; Whether a cladding system with a board type outer layer which is not … it needs to be considered as a significant part of the cladding system and therefore requires classification to …
Published on:
CEL00001340_Celotex Action Plan for use of FR5000 in above 18m applications..pdf [pdf]
… - BS 8414: 1 -Test method for non-loadbearing external cladding systems applied to the face of the building. Part 1 … BS 8414:2 -Test method for non-loadbearing external cladding systems fixed to and supported by a structural steel frame. Part 2 is concerned with rainscreen cladding on steel frame constructions. Predominantly new …
Published on:
HAR00010103_Exhibit BB_2 (7256-WEST_4_AB - - 26_11_2015.pdf) - Ben Bailey (Harley).pdf [pdf]
Published on:
BBA00011296_Phase 2 Module 2 - Written closing submission on behalf of The British Board of Agrement.pdf [pdf]
… BBA00011296_Phase 2 Module 2 - Written closing submission on behalf of The … Current BBA Certificates now provide the Euro fire classifications for a product on the front page. Where there … of Reynobond 55 PE produced a significantly worse fire classification than the rivetted version, this was not …
Published on:
Transcript 21 March 2022_0.pdf [pdf]
Published on:
Transcript 21 March 2022.pdf [pdf]
Published on:
MET00012525_BRE Global Client Report P109378-1012 – Interim - Dated 9th March 2018.pdf [pdf]
Published on:
BBA00010751_2019.09.05 Third witness statement of John Albon.pdf [pdf]
… as to the use to which K15 would be put within an external cladding system? If different, what was your own … in conjunction with masonry or weathertight ventilated cladding systems.' This agrees with my understanding. 15. … In relation to large-scale testing to BS 8414 of external cladding systems, and covering the entire period of your …
Published on:
IWS of Emanuela Disaro mother of Gloria Trevisan of Flat 202, 23rd Floor IWS00000543.pdf [pdf]
Published on:
NHB00001431_Michael Slattery Associates Fire Engineering Report for Glenthorne Rd window spandrel panels only, Extruded polystyrene & PPC aluminium_0.pdf [pdf]
… Envirowall Render System, brickwork and ra~nscreen cladding. All elements are installed on top of a steel frame … is used within the cavity for the brickwork and rainscreen cladding. The envirowall render system consists of expanded … applied to obtain the finished fagade. The rainscreen cladding on the 6th floor is an etalbond sandwich type …
Published on:
NHB00001431_Michael Slattery Associates Fire Engineering Report for Glenthorne Rd window spandrel panels only, Extruded polystyrene & PPC aluminium.pdf [pdf]
… Envirowall Render System, brickwork and ra~nscreen cladding. All elements are installed on top of a steel frame … is used within the cavity for the brickwork and rainscreen cladding. The envirowall render system consists of expanded … applied to obtain the finished fagade. The rainscreen cladding on the 6th floor is an etalbond sandwich type …
Published on: