CLG00000687_Email attachment - British Board of Agreement Certificate for Kingspan Kooltherm K15 Rainscreen Insulation Board (08_4582) 2013 - Revised Version_1.pdf [pdf]
… External masanry walls and Chapter 6.9 Curtain walling and cladding. Current NHBC guidance precludes the use of facade … ~n conlunctJon with masonry or weath÷rtight ventilated cladding systems 4 2 Care must be taken in the c~,,erall … to be used 4 5 The product, in con unction with an approved cladding is for use in any exposure zone, provided a …
Published on:
CLG00000687_Email attachment - British Board of Agreement Certificate for Kingspan Kooltherm K15 Rainscreen Insulation Board (08_4582) 2013 - Revised Version_0.pdf [pdf]
… External masanry walls and Chapter 6.9 Curtain walling and cladding. Current NHBC guidance precludes the use of facade … ~n conlunctJon with masonry or weath÷rtight ventilated cladding systems 4 2 Care must be taken in the c~,,erall … to be used 4 5 The product, in con unction with an approved cladding is for use in any exposure zone, provided a …
Published on:
BLAR00000001_Expert Report - Dr Barbara Lane - Sections 1, 2, 3 & 4_1.pdf [pdf]
… 2.17 Instructions 2-45 2.18 The failure of the Rainscreen cladding system 2-45 2.19 The consequences for the early … GRENFELL TOWER INQUIRY 2.26 Mitigating existing rainscreen cladding systems formed with polymeric materials 2-63 2.27 … have also included my own conclusions regarding whether the cladding system installed at Grenfell Tower complied with …
Published on:
BLAR00000001_Expert Report - Dr Barbara Lane - Sections 1, 2, 3 & 4_0.pdf [pdf]
… 2.17 Instructions 2-45 2.18 The failure of the Rainscreen cladding system 2-45 2.19 The consequences for the early … GRENFELL TOWER INQUIRY 2.26 Mitigating existing rainscreen cladding systems formed with polymeric materials 2-63 2.27 … have also included my own conclusions regarding whether the cladding system installed at Grenfell Tower complied with …
Published on:
KIN00008838_Witness Statement of Malcolm Paul Rochefort.pdf [pdf]
… although I don't recall if this included a rainscreen cladding product at the time. Following the acquisition of … to be an insulation product for use inside a rainscreen cladding system — this is purpose for which it was designed. … KIN00008838/9 Sotech Ltd ("Sotech"), a rainscreen cladding manufacturer. The test was carried out on 20 …
Published on:
ART00000914_Curtins Structural Performance Specification for the Design, Supply and Application of Overcladding Systems to Grenfell Tower®.pdf [pdf]
… Specification for the Design, Supply and Application of Overcladding Systems to Grenfell Tower®.pdf ART00000914_Curtins … Specification for the Design, Supply and Application of Overcladding Systems to Grenfell Tower®.pdf Specification … Specification For the Design, Supply and Application Of Overcladding Systems to Grenfell Tower For Studio E …
Published on:
ART00005791_Exhibit CL_208B - Chweechen Lim (Artelia) - Attachment_ Curtins’ structural performance specification for overcladding systems to Grenfell Tower_0.pdf [pdf]
… Curtins’ structural performance specification for overcladding systems to Grenfell Tower_0.pdf ART00005791_Exhibit … Curtins’ structural performance specification for overcladding systems to Grenfell Tower_0.pdf I Specification … Specification For the Design, Supply and Application Of Overcladding Systems to Grenfell Tower For Studio E …
Published on:
ART00005791_Exhibit CL_208B - Chweechen Lim (Artelia) - Attachment_ Curtins’ structural performance specification for overcladding systems to Grenfell Tower.pdf [pdf]
… Curtins’ structural performance specification for overcladding systems to Grenfell Tower.pdf ART00005791_Exhibit … Curtins’ structural performance specification for overcladding systems to Grenfell Tower.pdf I Specification … Specification For the Design, Supply and Application Of Overcladding Systems to Grenfell Tower For Studio E …
Published on:
ART00006318_Exhibit SC_249 - Simon Cash (Artelia) -Attachment_ Structural Performance Specification for Overcladding of Grenfell Tower dd. 1 March 2013.pdf [pdf]
… -Attachment_ Structural Performance Specification for Overcladding of Grenfell Tower dd. 1 March 2013.pdf … -Attachment_ Structural Performance Specification for Overcladding of Grenfell Tower dd. 1 March 2013.pdf I … Specification Forthe Design, Supply and Application Of Overcladding Systems to Grenfell Tower For Studio E …
Published on:
Fire Brigade Union - Closing Submissions INQ00000546.pdf [pdf]
… could break back into the building was covered in the Lakanal training package [T48/180:7]. 31) This senior … nor on how to assess the risk of self-evacuation after Lakanal House [T42/23:23], nor on how to get the best … could break back into the building was covered in the Lakanal training package [T48/180:7]. 31) This senior …
Published on:
KIN00004031_Exhibit DB_22 - Emails between Boon Brown Limited, Kingspan and others dated July 2015 with subject RE_150716_3359_01212_2014_HO Highgate Former Police Station.pdf [pdf]
… BR 135 Report No 291642.pdf; BCA GN 18 -Use of combustible cladding materials on residential building .... pdf; … 60mm K15 onto a masonry substrate behind 6mm cement Cladding Board • BS 8414-2 (Report No 297099) : 80mm K15 … onto a 12mm cement particle board behind non-combustible cladding ( Taylor Maxwell Terracotta) • BR 135 (Report No …
Published on:
FOA00000004_Phase 2 Module 5 and Module 6 Part 1 (Firefighting) - Written Closing Submissions on behalf of the Fire Officers' Association and Richard Welch.pdf [pdf]
… FOA00000004_Phase 2 Module 5 and Module 6 Part 1 (Firefighting) - Written Closing Submissions on behalf of … RW's actions on the night; Paragraphs 24 - 38. Mr McGuirk's report; Paragraphs 43 - 45. The viability of evacuation on …
Published on:
KIN00008227_Exhibit ADH_12 - Routes to Compliance_ Fire Safety Technical Bulletin, fifth issue dated May 2018_0.pdf [pdf]
… • BS 8414-1: 2015+A 1: 2017 (Fire performance of external cladding systems. Test method for non-loadbearing external cladding systems applied to the masonry face of a building); … • BS 8414-2: 2015+A 1: 2017 (Fire performance of external cladding systems. Test method for non-loadbearing external …
Published on:
EXO00002124_Phase 2 Modules 1 & 2 - Written closing submission on behalf of Exova (UK) Limited.pdf [pdf]
… • Section II identifies the steps by which an unlawful cladding system came to be designed, approved, and …
Published on:
EXO00002124_Phase 2 Modules 1 & 2 - Written closing submission on behalf of Exova (UK) Limited_0.pdf [pdf]
… • Section II identifies the steps by which an unlawful cladding system came to be designed, approved, and …
Published on:
RYD00082733_JRP Site Inspection Report.pdf [pdf]
… 2 Plasterers 2 Labourer 3 Hoist Operator 0 Painters 0 Cladding Fixer 7 Lift Operators 0 Duck Work Fitters 0 … progressing with the tendered detail of the top roof new cladding details and panels are being procured. KCTMO to … South elevation has just started with the fitting of the cladding bracket. Rydon's are behind on the internal …
Published on:
BBA00010775_Exhibit JD_3 - Thickness restriction.pdf [pdf]
… in a draft for insulation used as part of a rain screen cladding system. Extracted from the attached draft: 'in conjunction with masonry or weathertight ventilated cladding systems generally up to 18 metres, although the 60 … one. Of course, K15 is typically for ventilated rainscreen cladding systems and that is the product's primary use. …
Published on:
BBA00010772_Exhibit GR_1 - Advice re insulation thickness.pdf [pdf]
… in a draft for insulation used as part of a rain screen cladding system. Extracted from the attached draft: 'in conjunction with masonry or weathertight ventilated cladding systems generally up to 18 metres, although the 60 … in conjunction with masonry or weathertight ventilated cladding systems.' In the traditional masonry building …
Published on:
KIN00002535_Exhibit RHB2_16 - Letter from Ian Davis of the NHBC to Tony Millichap dated 5 February 2015 with subject _RE_ The use of Kooltherm K15 Rainscreen Board in facades above 18.0m__0.pdf [pdf]
… accordance with BCA Guidance Note 18 - Use of Combustible Cladding Materials on Residential Buildings (copy enclosed) … acceptable use of combustibJe materials within the external cladding system. Where a building exceeds 18m in height, AD … paragraph 12,7 However, if they are included as part of a cladding system being tested to BR135 & BS8414, the complete …
Published on: