TMO00833024_John Rowan _Site Inspection Report No 25_.pdf [pdf]
… on site: No: Trades on site: No: Site Manager 4 Painters 6 Cladding Fixer 12 Carpenters 6 Electrician 5 Floor Layers 1 … driller 1 Asbestos Removal 1 Comments: Still 12 External cladding fixers on site, which is helping push on the external cladding. Plant on site: No: Plant on site: No: Plant on …
Published on:
RYD00037742_Correspondence between Siderise, Harley, Exova, RBKC, Rydon and Studio E regarding Cavity Barriers and Fire stopping at Grenfell Tower attaching Studio E drawings_1.pdf [pdf]
… may have stemmed from. I have included also the cladding contractors detail to this specific area also. … your email and for the attached drawing, showing typical cladding details. The matter has now become more clearer. I … the mezzanine plus one floor, as it my impression that the cladding I floor junction detail for those particular floors …
Published on:
BBA00003353_Email chain involving the Scottish Association of Building Standards Managers (SABSM) and BBA. SABSM raise issues about BBA certificate 08_4582 (K15) relating to lack of consultati.pdf [pdf]
… 2010 12:20 George Lee John Albon Subject: FW: External Cladding - Kingspan K15 Kooltherm Rainscreen Cladding Board - BBA 08/4582 Attachments: Agrement … Simon Wroe Cc: Jon Denyer; Chris Hunt Subject: FW: External Cladding - Kingspan K15 Kooltherm Rainscreen Cladding Board …
Published on:
Exhibit ML5 - Letter to MHCLG SoS MOL00000125.pdf [pdf]
… should no longer be an acceptable route to compliance for cladding systems in England. The fire at Grenfell Tower on … Judith did not recommend a ban on the use of combustible cladding in tall buildings. Alongside a ban on desktop … the ensuing contagion of remediation works needed to remove cladding on tower blocks, their use undermines public …
Published on:
KIN00005705_LABC System Approval Certificate for K15 Rainscreen Board and explanatory notes_1.pdf [pdf]
… Service System Approval- External Walls of Ralnscreen Cladding Incorporating Klngspan Kooltherm K151nsulation … masonry or metal framed walls as part of a rainscreen cladding system. Under this system approval certificate, … the system, the inner substrata and the outer rainscreen cladding layer being variables which can be selected on the …
Published on:
KIN00005705_LABC System Approval Certificate for K15 Rainscreen Board and explanatory notes_0.pdf [pdf]
Published on:
KIN00005705_LABC System Approval Certificate for K15 Rainscreen Board and explanatory notes.pdf [pdf]
… Service System Approval- External Walls of Ralnscreen Cladding Incorporating Klngspan Kooltherm K151nsulation … masonry or metal framed walls as part of a rainscreen cladding system. Under this system approval certificate, … the system, the inner substrata and the outer rainscreen cladding layer being variables which can be selected on the …
Published on:
Transcript 14 September 2021.pdf [pdf]
… deal with Dr Lane’s written evidence, tying 8 Exova to the cladding system, and the rowing back from 9 her position as … issues in relation to the façade. 6 Through much of 2013, cladding materials were 7 discussed between KCTMO, Studio E, … were taking place. 11 Specifications for the proposed cladding system, with 12 details of the proposed materials …
Published on:
BBA00000038_Certificate 08_4582 Product Sheet 1 for Kingspan Insulation Kooltherm K15 Rainscreen Insulation Board_0.pdf [pdf]
… in conjuncfion wifh masonry or weafherfighf venfilafed cladding sysfems. AGREMENT CERTIFICATION INCLUDES: • factors … External masonry walls and Chapter 6.9 Curtain walling and cladding. Current NHBC guidance precludes the use of fagade … 4 Superstructure, Sub-section External walls - Render/cladding/curtain walling. 2 of BBA00000038 0002 …
Published on:
BBA00000038_Certificate 08_4582 Product Sheet 1 for Kingspan Insulation Kooltherm K15 Rainscreen Insulation Board.pdf [pdf]
… in conjuncfion wifh masonry or weafherfighf venfilafed cladding sysfems. AGREMENT CERTIFICATION INCLUDES: • factors … External masonry walls and Chapter 6.9 Curtain walling and cladding. Current NHBC guidance precludes the use of fagade … 4 Superstructure, Sub-section External walls - Render/cladding/curtain walling. 2 of BBA00000038 0002 …
Published on:
BRE00047571_2021.10.22 Witness Statement of Sarah Colwell.pdf [pdf]
… Kooltherm KI5 insulation ("KIS"), under the BRE reference 220876. Prior to that test, had you, or as far as you were … of or content of a BR 135 Classification Report for Test 220876? 299 I recall there being general discussions about … Kooltherm KI5 insulation ("KIS"), under the BRE reference 220876. Prior to that test, had you, or as far as you were …
Published on:
INQ00014964_SP FIRE 105—Method for fire testing of façade materials, Dnr 171‐79‐360 Department of Fire Technology, Swedish National Testing and Research Institute.pdf [pdf]
… 1994-09-09 Page 1(16) External wall assemblies and facade claddings Reaction to fire Scope This SP method specifies a … and construction of external wall assemblies or facade claddings, when exposed to fire from a simulated apartment … and material and the fire spread (flame spread) in the wall/cladding can be studied. 2 Field of application The test …
Published on:
RBK00059519_RBKC - Phase 2 Module 2 Opening Submissions.pdf [pdf]
… the first high-rise residential buildings in the UK with a cladding system which included insulation which was not of … two previous projects influenced the decision as to which cladding panel to use at Grenfell Tower Studio E met CEP on … 17 April 2013 Studio E sent its client (the TMO) details of cladding options which included 5 different ACM panels~° On …
Published on: