BRE00043756_Exhibit DC_117 - Email from Ronnie King concerning presentation on Lakanal House to the All Party Parliamentary Fire Safety & Rescue Group, dated 7 July 2014..pdf [pdf]
… BRE00043756_Exhibit DC_117 - Email from Ronnie King concerning presentation on Lakanal House to … 79 at Lakanal House, having only a surface spread of flame classification, rather than a degree of fire resistance; as … to be undertaken, and which could be used to confirm that a class ’O’ surface spread of flame, would have not made any …
Published on:
LFB00121149_Exhibit JFS_14 - FSG Acquisition Training Materials – FSG2 (2020_2021) - Lesson - PN790 and Appendix 1.pdf [pdf]
… LFB00121149_Exhibit JFS_14 - FSG Acquisition Training Materials – FSG2 (2020_2021) - Lesson - PN790 … will not leave that location. If they are not directly be classed as an FSG call affected by fire, heat or smoke, the … will not leave that location. If they are not directly be classed as an FSG call affected by fire, heat or smoke, the …
Published on:
MET00065109_Exhibit VGP_1 - Graham Pollard Exhibit to 2nd MPS witness statement.pdf [pdf]
… MET00065109_Exhibit VGP_1 - Graham Pollard Exhibit to 2nd MPS witness statement.pdf … DOCUMENT RECORD PRINT Other Document URN D27591 Medium Class: L96 CONSTRUCTION - INTERVIEWS AND STATEMENTS COPY OF … DOCUMENT RECORD PRINT Other Document URN D27591 Medium Class: L96 CONSTRUCTION - INTERVIEWS AND STATEMENTS COPY OF …
Published on:
LABC0001842_RD165 - LABC Registered Details, Drawing and Document List for Kingspan Kooltherm K15.pdf [pdf]
… LABC0001842_RD165 - LABC Registered Details, Drawing and Document List for Kingspan Kooltherm K15.pdf … B or Scottish Technical Handbook). The product has a "Class 0" or "Low Risk" classification in accordance with the requirements of …
Published on:
NHB00002720_Email correspondence between Graham Perrior (NHBC), Jon Denyer, John Albon, and Gayetree Ramokrun (all of the BBA), Steve Evans, Dave White, John Lewis, Ian Davie, and Mark Jones (.pdf [pdf]
… NHB00002720_Email correspondence between Graham Perrior (NHBC), Jon Denyer, … any ambiguity is removed by clarifying the refe[ence to Class 0 and low risk. The updated wording should also appear … any ambiguity is removed by clarifying the refe[ence to Class 0 and low risk. The updated wording should also appear …
Published on:
HBC00000035_Appendix F - LABC Registered Details (RD 165 Kingspan Kooltherm K15) Drawing and Document List.pdf [pdf]
Published on:
CEL00001040_Internal Celotex email regarding use of RS5000, BBA certification and the NHBC’s guidance on the use of insulation in rainscreen cladding systems_0.pdf [pdf]
… CEL00001040_Internal Celotex email regarding use of RS5000, BBA certification and the NHBC’s guidance on the … 6 Guidance on Curtain Wall & Cladding. RSSOOO is not classed as a whole system but neither would any other …
Published on:
KIN00011603_Kingspan Thermapitch TP10 Detailed specification form Second Issue.pdf [pdf]
… KIN00011603_Kingspan Thermapitch TP10 Detailed specification form Second Issue.pdf KIN00011603_Kingspan Thermapitch … TP10 and its rigid thermoset insulation core, are Class 1, as defined by the Building Regulations. Further … TP10 and its rigid thermoset insulation core, are Class 1, as defined by the Building Regulations. Further …
Published on:
KIN00009547_LABC Registered Details Drawing and Document list for Kingspan K15 Rainscreen Board RD Reference No. RD165_0.pdf [pdf]
… A The product is suitable for use with a variety of outer claddings, including rainscreens (pressure equalised or … A The product is suitable for use with a variety of outer claddings, including rainscreens (pressure equalised or …
Published on:
KIN00020857_Exhibit AP_58 - LABC Registered Details Drawing and Document List.pdf [pdf]
… AP_58 - LABC Registered Details Drawing and Document List.pdf KIN00020857_Exhibit AP_58 - LABC Registered … B or Scottish Technical Handbook). 4. The product has a "Class 0" or "Low Risk" classification in accordance with the requirements of …
Published on:
KIN00000535_Exhibit AP_14 - Adrian Pargeter (Kingspan).pdf [pdf]
… (Kingspan).pdf LABC REGISTERED DETAILS DRAWING AND DOCUMENT LIST RD Reference Number RD165 Kingspan Insulation … B or Scottish Technical Handbook). 4. The product has a "Class 0" or "Low Risk" classification in accordance with the requirements of …
Published on:
Transcript 8 November 2022 .pdf [pdf]
Published on:
GTI - Day 74 - Amended.pdf [pdf]
Published on:
Transcript 19 November 2020.pdf [pdf]
… Transcript 19 November 2020.pdf Transcript 19 November 2020.pdf Grenfell … 17 would be very basic , such as , ” Is your product 18 class 1?”, for example, and to answer that would be 19 … board were listed and it would 21 confirm the product to be class 1. 22 Q. Yes, I see. 23 Now, you say in paragraph 9, …
Published on:
KIN00005240_Email exchange between Ivor Meredith of Kingspan and Baris Facades & Linings Ltd discussing the suitability of Kooltherm K15 on buildings above 18 meters vis a vis the test carried.pdf [pdf]
… KIN00005240_Email exchange between Ivor Meredith of Kingspan and Baris Facades & Linings Ltd … insulation conforms. We acknowledge that Kooltherm is classified as Class 0 for surface fire spread. But does this constitute …
Published on:
KIN00002592_Kingspan responds to Bandk's query re K15's suitability with a copy of K15's BBA certificate and a general description of the product uses..pdf [pdf]
… KIN00002592_Kingspan responds to Bandk's query re K15's suitability with a copy of … internally and by your client. Kooltherm K15, although not classed as non combustible, it is classified as Class 0 or 'low risk' as defined by the …
Published on:
CCS0923434692-004_GTI Phase 2_Report Overview Chinese_HQPC.pdf [pdf]
… CCS0923434692-004_GTI Phase 2_Report Overview Chinese_HQPC.pdf CCS0923434692-004_GTI Phase … 前「批准文件 B」(Approved Document B) 所載的外牆嵌板系統相關防火安全要求(從而 撤銷「0 級」(Class 0))。 2.6 該部門也沒適當考慮 2001 年大規模測試所發現可怕結果,即「未改性聚乙烯芯鋁大廈 … 年進一步測試 Reynobond 55 PE 後,判斷無論以「鉚釘」或「卡式錄音帶」 形式,都僅將獲「E 級」(Class E) 認證。可是,Arconic 並沒向身在英國的客戶或 BBA, 傳送這些資料。Arconic …
Published on:
RKI00000012_Minutes - All Party Parliamentary (Fire Safety & Rescue) Group Meeting - DCLG Minister attendance to discuss updating BRE Research re effectiveness of sprinklers in residential pre.pdf [pdf]
… - All Party Parliamentary (Fire Safety & Rescue) Group Meeting - DCLG Minister attendance to discuss updating … on the outside wall at Lakanal House need only to have a class 'O' certification instead of having a measure of Fire … the Regulations; together with the removal of the 'O' classification of window panels on outside walls of tall …
Published on: