Transcript 22 March 2022.pdf [pdf]
… 22 March 2022.pdf Transcript 22 March 2022.pdf GRENFELL TOWER INQUIRY RT Day 252 March 22, 2022 Opus 2 - Official … in order to incorporate a new European system 14 of classification in 13501 relating to roof coverings 15 there. … 24 apply, but we have had a very large dependency on the 25 Class 0 contrivance for building products since the 85 1 …
Published on:
KIN00008790_Witness statement of Joel Clarke (Kingspan).pdf [pdf]
… KIN00008790_Witness statement of Joel Clarke (Kingspan).pdf KIN00008790_Witness statement of … as part of a certain built-up system and has achieved a Class 0 fire rating as a result of testing to British …
Published on:
LABC0000068_H+H fire Desktop BR135 Report on Brick External Wall Assessment using K15 Insulation prepared for Kingspan..pdf [pdf]
… LABC0000068_H+H fire Desktop BR135 Report on Brick External Wall Assessment using K15 Insulation …
Published on:
BLM00000131_Email chain between Booth Muirie, BRE Global, DCLG and Bath concerning regulations and testing relating to the use of cladding panels of buildings exceeding 18 meters.pdf [pdf]
… BLM00000131_Email chain between Booth Muirie, BRE Global, DCLG and Bath concerning … panels were used on the building? lt suggests they were class A2 or B, however the evidence suggests they may not … has a height of over 18m then a cladding material meeting Class 0 (national class) or B-s3, d2 or better European …
Published on:
INQ00014949_Inquiry created transcript of Q & A session at the Facades Conference held on 13 January 2016 Co-hosted by BRE and Siderise - original video URN SIL00010066.pdf [pdf]
… INQ00014949_Inquiry created transcript of Q & A session at the Facades Conference held on 13 … we actually do is test the cladding systems and publish a classification to BR135. Now that quotes pass/fail criteria … BR135 but there isn’t actually a defined pass/fail in the classification document currently. So we report it, report …
Published on:
LFB00032942_Exhibit SFD_1 - Letter from the RBKC on 11th November 2014_0.pdf [pdf]
… LFB00032942_Exhibit SFD_1 - Letter from the RBKC on 11th November 2014_0.pdf LFB00032942_Exhibit SFD_1 - Letter from …
Published on:
LFB00032942_Exhibit SFD_1 - Letter from the RBKC on 11th November 2014.pdf [pdf]
… LFB00032942_Exhibit SFD_1 - Letter from the RBKC on 11th November 2014.pdf LFB00032942_Exhibit SFD_1 - Letter from the …
Published on:
HBC00000039_Appendix J - Kingspan Kooltherm K15 Product Literature dated March 2011.pdf [pdf]
… HBC00000039_Appendix J - Kingspan Kooltherm K15 Product Literature dated March 2011.pdf … BR135 and is therefore acceptable for use above 18 metres • Class 0 fire rating • Class 0 fire rated insulation core • Negligible smoke …
Published on:
BRE00003528_Kingspan Kooltherm-K15-Rainscreen-Board marketing literature.pdf [pdf]
… BRE00003528_Kingspan Kooltherm-K15-Rainscreen-Board marketing literature.pdf … is therefore acceptable for use above 18 metres ¯ ¯ ¯ ¯ ¯ Class 0 fire rating Class 0 fire rated insulation core Negligible smoke …
Published on:
KIN00008381_Kingspan brochure entitled _Kooltherm K15 Rainscreen Board - Insulation for rainscreen cladding systems_, 9th issue, March 2011.pdf [pdf]
… KIN00008381_Kingspan brochure entitled _Kooltherm K15 Rainscreen Board - Insulation … BR135 and is therefore acceptable for use above 18 metres • Class 0 fire rating • Class 0 fire rated insulation core • Negligible smoke …
Published on:
KIN00000063_Exhibit DB_58, Exhibit PJH_23, Exhibit AP_7 - Kingspan publication “Kooltherm K15 Rainscreen Board” Ninth Issue March 2011_1.pdf [pdf]
… DB_58, Exhibit PJH_23, Exhibit AP_7 - Kingspan publication “Kooltherm K15 Rainscreen Board” Ninth Issue March … 35 and is therefore acceptable for use above 18 metres • Class 0 fire rating • Class 0 fire rated insulation core • Negligible smoke …
Published on:
KIN00000063_Exhibit DB_58, Exhibit PJH_23, Exhibit AP_7 - Kingspan publication “Kooltherm K15 Rainscreen Board” Ninth Issue March 2011.pdf [pdf]
… DB_58, Exhibit PJH_23, Exhibit AP_7 - Kingspan publication “Kooltherm K15 Rainscreen Board” Ninth Issue March … 35 and is therefore acceptable for use above 18 metres • Class 0 fire rating • Class 0 fire rated insulation core • Negligible smoke …
Published on:
KIN00000063_Exhibit DB_58, Exhibit PJH_23, Exhibit AP_7 - Kingspan publication “Kooltherm K15 Rainscreen Board” Ninth Issue March 2011_0.pdf [pdf]
… DB_58, Exhibit PJH_23, Exhibit AP_7 - Kingspan publication “Kooltherm K15 Rainscreen Board” Ninth Issue March … 35 and is therefore acceptable for use above 18 metres • Class 0 fire rating • Class 0 fire rated insulation core • Negligible smoke …
Published on:
BBA00010730_BBA Exhibit JA_10 (B) - Draft BBA Certificate for Reynobond Architecture Wall Cladding Panels.pdf [pdf]
… BBA00010730_BBA Exhibit JA_10 (B) - Draft BBA Certificate for Reynobond Architecture Wall Cladding Panels.pdf BBA00010730_BBA …
Published on:
BBA00011272_Assessment of Production - Agreed Quality Plan for Promat TL Board.pdf [pdf]
… BBA00011272_Assessment of Production - Agreed Quality Plan for Promat TL Board.pdf … Manager. Incoming product, raw Identification (type, class, Original supplier Acceptance limits materials and … Quality Method used Line side weigh scale Steel Tape (Class II) Vernier Visual inspection Frequency Every 30 …
Published on:
HBC00000033_Appendix D - Kingspan Kooltherm K15 Product Literature dated November 2008.pdf [pdf]
… HBC00000033_Appendix D - Kingspan Kooltherm K15 Product Literature dated November 2008.pdf … can be equiVi!lent to mineral fipre. • Achieves a Class 0 fire rating to the Building Regulations anq LQw Risk …
Published on:
KIN00008809_Exhibit ADH_52_ Emails between St James Group Limited, Exova and Kingspan in relation to a desktop study paid for by Kingspan and carried out by Exova on Hornsey Depot in 2015-6 wi_0.pdf [pdf]
… KIN00008809_Exhibit ADH_52_ Emails between St James Group Limited, Exova and Kingspan in relation to a desktop … of VitraCore G2 in lieu of Vitrabond FR. VitraCore G2 is a Class A2 ACM product and FR is Class B. Can you confirm that this product will still result …
Published on:
GTI - Day 64.pdf [pdf]
… GTI - Day 64.pdf GTI - Day 64.pdf Grenfell Tower Inquiry Day 64 November 3, 2020 Opus 2 International - … wall is concerned, genuinely 11 compliant with the fire classifications ? 12 A. Correct . 13 Q. Can I ask you then … documents. 7 A. Yes. 8 Q. Yes. 9 Now, you address the fire classification of the zinc 10 Proteus cladding panels and …
Published on:
INQ00015204_Approved Document L2B - Conservation of fuel and power in existing buildings other than dwellings.pdf [pdf]
… INQ00015204_Approved Document L2B - Conservation of fuel and power in … display windows will be found in buildings in Planning Use Classes A 1, A2, A3 and D2 as detailed in Table 1. Approved Document L2B Table 1 Planning Use Classes Class Use A 1 Shops: including retail-warehouse, …
Published on:
LFB00087792_Tender for a study in to the experience and the operation of the RRO - proposal by BRE Global.pdf [pdf]
… LFB00087792_Tender for a study in to the experience and the operation of the RRO … to consider whether a single regime for different classes of premises is sensible 1.4.4. To examine whether … proposals upon whether a single regime for different classes of premises is sensible or whether the separation of …
Published on: