CEL00000416_Rainscreen Cladding RS5000 Compliance Guide building above 18 meters February 2015_1.pdf [pdf]
… CEL00000416_Rainscreen Cladding RS5000 Compliance Guide building above 18 meters February 2015_1.pdf … spread on the outside of a building envelope. These are classified as: ~ Initiation of the fire ~ Fire breakout ~ … Annex B of BR 135 establishes the performance criteria and classification for testing to BS 8414-2: 2005. Performance …
Published on:
NHB00001252_NHBC Technical Services Building Regulations Technical Guidance Note – Acceptability of masonry skinned wall constructions containing combustible materials in high rise buildin_2.pdf [pdf]
… NHB00001252_NHBC Technical Services Building Regulations Technical Guidance Note – Acceptability of masonry skinned wall constructions containing combustible …
Published on:
NHB00001252_NHBC Technical Services Building Regulations Technical Guidance Note – Acceptability of masonry skinned wall constructions containing combustible materials in high rise buildin_1.pdf [pdf]
… NHB00001252_NHBC Technical Services Building Regulations Technical Guidance Note – Acceptability of masonry skinned wall constructions containing combustible …
Published on:
CEL00000416_Rainscreen Cladding RS5000 Compliance Guide building above 18 meters February 2015.pdf [pdf]
… CEL00000416_Rainscreen Cladding RS5000 Compliance Guide building above 18 meters February 2015.pdf … spread on the outside of a building envelope. These are classified as: ~ Initiation of the fire ~ Fire breakout ~ … Annex B of BR 135 establishes the performance criteria and classification for testing to BS 8414-2: 2005. Performance …
Published on:
CEL00000012_Celotex RS5000 - Rainscreen Cladding Compliance Guide with Approved Document B_1.pdf [pdf]
… CEL00000012_Celotex RS5000 - Rainscreen Cladding Compliance Guide with … spread on the outside of a building envelope. These are classified as: ~ Initiation of the fire ~ Fire breakout ~ … Annex B of BR 135 establishes the performance criteria and classification for testing to BS 8414-2: 2005. Performance …
Published on:
NHB00001252_NHBC Technical Services Building Regulations Technical Guidance Note – Acceptability of masonry skinned wall constructions containing combustible materials in high rise buildin_3.pdf [pdf]
… Alliance (BCA)_.Guidance Note 18-::- Use of Combustible Cladding Materials _ { Formatted: Font: Italic on Buildings … Note 18 · Option 3 allows for a desktop assessment of the cladding system to be provided to demonstrate compliance as … produced to provide advice to builders on the most common cladding types encountered on tall buildings where NHBC …
Published on:
CLG10006010_Email from Richard Harral to Brian Martin RE_ Building Regulations - Facades.pdf [pdf]
… CLG10006010_Email from Richard Harral to Brian Martin RE_ Building Regulations - … for materials of limited combustibility such that Class O materials are being now considered accepted. I … that the insulation should not add to the fire load, all class O materials are unable to sustain combustion but are …
Published on:
PAN00000017_PSL Submission.pdf [pdf]
… PAN00000017_PSL Submission.pdf PAN00000017_PSL Submission.pdf Grenfell Tower Inquiry … for which we would quote. 1 PAN00000017 _0001 2) Fire Classification of Panels 2.1) PSL do not manufacture a panel … of designing the panel composition. These may include: - a) Class 1 Surface Spread of Flame b) Class 'O' to Building …
Published on:
NHB00001252_NHBC Technical Services Building Regulations Technical Guidance Note – Acceptability of masonry skinned wall constructions containing combustible materials in high rise buildin_0.pdf [pdf]
… NHB00001252_NHBC Technical Services Building Regulations Technical Guidance Note – Acceptability of masonry skinned wall constructions containing combustible …
Published on:
NHB00001252_NHBC Technical Services Building Regulations Technical Guidance Note – Acceptability of masonry skinned wall constructions containing combustible materials in high rise buildin.pdf [pdf]
… NHB00001252_NHBC Technical Services Building Regulations Technical Guidance Note – Acceptability of masonry skinned wall constructions containing combustible …
Published on:
TRI000001377_Technical data sheet for Enviroboards Fire Board and Uni Board.pdf [pdf]
… TRI000001377_Technical data sheet for Enviroboards Fire Board and Uni Board.pdf TRI000001377_Technical …
Published on:
PAN00000017_PSL Submission to Grenfell Tower Inquiry.pdf [pdf]
… PAN00000017_PSL Submission to Grenfell Tower Inquiry.pdf PAN00000017_PSL Submission … we would quote. PAN00000017 0001 PAN00000017/1 2) Fire Classification of Panels 2.1) PSL do not manufacture a panel … designing the panel composit ion. These may include: - a) Class 1 Surface Spread of Flame b) Class ' 0 ' to Building …
Published on:
KIN00009188_internal Kingspan emails regarding the use of K15 for Devereux Architects and its Middlehaven project_0.pdf [pdf]
… KIN00009188_internal Kingspan emails regarding the use of K15 for Devereux Architects and its Middlehaven … the Pavatherm BBA cert (certificate 08/4549 quotes the fire classification as class E under the Euroclass classifications , therefore if …
Published on:
KIN00020725_Exhibit PJH_9 PPDS Review Meeting Minutes – 1 December 2006.pdf [pdf]
… REVIEW MEETING MINUTES Date: 1st December 2006 Present: Malcolm Rochefort, Christine Nichol (minutes), Paul Sykes. … outstanding. Notification re-sent during meeting. 103 Euro Class B K8 for Holland - the project files need to be … PPDS 135. CN to contact RZ re progress on PPDS35. 110 K10 class '0'- project complete. PJH access problems meant he …
Published on:
CEL00001239_Celotex Rainscreen Cladding Compliance Guide when specifying RS5000 in buildings above 18 metres..pdf [pdf]
… CEL00001239_Celotex Rainscreen Cladding Compliance Guide when specifying … spread on the outside of a building envelope. These are classified as: ~ Initiation of the fire ~ Fire breakout ~ … Annex B of BR 135 establishes the performance criteria and classification for testing to BS 8414-2: 2005. Performance …
Published on:
CEL00000416_Rainscreen Cladding RS5000 Compliance Guide building above 18 meters February 2015_0.pdf [pdf]
… CEL00000416_Rainscreen Cladding RS5000 Compliance Guide building above 18 meters February 2015_0.pdf … spread on the outside of a building envelope. These are classified as: ~ Initiation of the fire ~ Fire breakout ~ … Annex B of BR 135 establishes the performance criteria and classification for testing to BS 8414-2: 2005. Performance …
Published on:
CEL00000012_Celotex RS5000 - Rainscreen Cladding Compliance Guide with Approved Document B_0.pdf [pdf]
… CEL00000012_Celotex RS5000 - Rainscreen Cladding Compliance Guide with … spread on the outside of a building envelope. These are classified as: ~ Initiation of the fire ~ Fire breakout ~ … Annex B of BR 135 establishes the performance criteria and classification for testing to BS 8414-2: 2005. Performance …
Published on:
CEL00002047_Celotex Rainscreen Compliance Guide - RS5000 over 18m+.pdf [pdf]
… CEL00002047_Celotex Rainscreen Compliance Guide - RS5000 over 18m+.pdf … spread on the outside of a building envelope. These are classified as: ~ Initiation of the fire ~ Fire breakout ~ … Annex B of BR 135 establishes the performance criteria and classification for testing to BS 8414-2: 2005. Performance …
Published on:
INQ00014107_Approved_Document_B_2000_Edition___in_force_1_July_2000_until_1_March_2003.pdf [pdf]
… group. 84 i. Rooflights: separate Tables are given for Class 3 and TP(a)/(b) plastics rooflights and the provisions relating to Class 3 rooflights on industrial buildings has been … 56 Introduction 56 Section 7: Wall and ceiling linings 57 Classification of linings 57 Variations and special …
Published on: