ART00008193_Asbestos_ The Survey Guide, First Edition, published by the Health and Safety Executive.pdf [pdf]
… ART00008193_Asbestos_ The Survey Guide, First Edition, published by the Health … be competent to do all the relevant work and tasks in this class of surveys (see Section 2: Competence and quality … groups. Other properties constructed pre-2000 should be classed as possibly containing ACMs (unlessthere is …
Published on:
ART00008237_Asbestos_ The Survey Guide (First Edition) published by the Health and Safety Executive.pdf [pdf]
Published on:
Submissions for Procedural Hearing 3 2018.zip [zip]
… and purpose of the stay put policy; b) Their relevant post-Lakanal training - both received, if any, and given - … for signs in others; c) Any part they may have played post-Lakanal in updating or amending any of the LFB’s policy … Instructed by Thompsons Solicitors Congress House, Great Russell Street, London. WC1B 3LW …
Published on:
ART00008398_Exhibit AD_235 - Attachment_ Grenfell Tower Mechanical, Electrical and Public Health Stage D Report prepared by Max Fordham dd. 22 November 2012.pdf [pdf]
… ART00008398_Exhibit AD_235 - Attachment_ Grenfell Tower Mechanical, Electrical and Public Health Stage D Report … GWPL achieves efficiencies of up to 165% wh ich means it is classed as a low carbon heat sou rce. The GWPL-38 is … the nursery as no ma in reception area is provided and no class room or lecture areas can be identified from the …
Published on:
Transcript 4 April 2022.pdf [pdf]
… 4 April 2022.pdf Transcript 4 April 2022.pdf GRENFELL TOWER INQUIRY RT Day 259 April 4, 2022 Opus 2 - Official … 2013. 10 Q. Were you ever told anything about national class 0, what 11 it was, what it meant, or how it was … the Regulations; together with the removal 22 of the ’0’ classification of window panels on outside 23 walls of tall …
Published on:
LFB00034866_PAS 79 2012, entitled _Fire risk assessment - Guidance and a recommended methodology_, Third Edition August 2012.pdf [pdf]
… 79 2012, entitled _Fire risk assessment - Guidance and a recommended methodology_, Third Edition August 2012.pdf … time (see 3.21) needs to be shorter than the ASE£ 3.7 class A fires fires involving solid materials, usually of an … embers NOTE These are normally carbonaceous fires. 3.8 class B fires fires involving liquids or liquefiable solids …
Published on:
RYD00001486_Rydon completed Pre-Qualification Questionnaire draft version._0.pdf [pdf]
… RYD00001486_Rydon completed Pre-Qualification Questionnaire draft version._0.pdf RYD00001486_Rydon … we do to create a quality finish; • Offer a first class property handover and aftercare service. Management of …
Published on:
UKAS0011436_Exhibit JL_6 - BRE 2021 SU1 Assessment Report.pdf [pdf]
… UKAS0011436_Exhibit JL_6 - BRE 2021 SU1 Assessment Report.pdf UKAS0011436_Exhibit JL_6 - BRE 2021 SU1 Assessment … system had not yet been updated to the 2020 version and the classification standard for which this test is used required … standard and ISO/IEC 17025:2017. BS EN 11925-2 Test and classification to EN 13501-1:2018 test file. The test …
Published on:
TMO10030810_TMO document entitled _Modular Management Agreement for Tenant Management Organisation_ Vol 1 - The agreement.pdf [pdf]
… TMO10030810_TMO document entitled _Modular Management … marital or civil partnership status, sexuality, age, class, appearance, religion or belief, responsibility for … criminal convictions, being HIV positive or having AIDS, class or appearance or any other matter which causes any …
Published on:
PHYS0000005_Part 4 of Paul Hyett's Supplemental Report.pdf [pdf]
… PHYS0000005_Part 4 of Paul Hyett's Supplemental Report.pdf PHYS0000005_Part 4 … linings should meet a fire rating standard of ‘Class 1 or Class C-‐s3, d2’ {SEA00000169/249}. 4.6.33 Most …
Published on:
CEL00002865_Alcimed - Presentation on the issues associated to PUR and PIR foams.pdf [pdf]
… CEL00002865_Alcimed - Presentation on the issues associated to PUR and PIR foams.pdf … materials should be built with the noncombustible class", KFPA, KR Source: interviews 07/03/2011 45 … droplets... The product is then graded following the Euroclass classification. Non-devastating fire is not identified …
Published on:
Public-meeting-19-July-2017.odt [odt]
… Public-meeting-19-July-2017.odt Public-meeting-19-July-2017.odt 1 Wednesday, 19 July … have been clear for many years, that 3 buildings that are classed as high-rise, which is over 4 18 metres or seven floors, should absolutely be EN13501 5 class A2, which is limited combustibility. That's been 6 …
Published on:
TMO00843943_FRA Adair Tower Sept 2016.pdf [pdf]
… TMO00843943_FRA Adair Tower Sept 2016.pdf TMO00843943_FRA … risk assessment. The roof level of the building has been classed as one compartment with no fire rated areas or rooms … precautions? Comments or observations: YES NO N/A I have classed this as a single occupied residential building there …
Published on:
TMO00842081_TMO document entitled Regulatory Reform (Fire Safety Order 2005) Fire Risk Assessment for Trellick Tower by Carl Stokes..pdf [pdf]
… at each end of the link way. The central staircase is also housed within this central core and fire separated from the … The reports, including the Coroner's ones issued after the Lakanal House fire (Camberwell London) , Shirley Heights … The reports, including the Coroner's ones issued after the Lakanal House fire (Camberwell London) , Shirley Heights …
Published on:
NHB00003522_Phase 2 Module 6 Part 2 (Gov, Testing, FRA) - Written Closing Submissions on behalf of the National House Building Council.pdf [pdf]
… NHB00003522_Phase 2 Module 6 Part 2 (Gov, Testing, FRA) - Written Closing … (ii) the fact that (unbeknownst to NHBC staff) there was a Class B 100% PE core ACM panel on the market in 2016 and … ongoing training in his field. 14 Ms Marshall holds a first-class degree in building engineering, qualified as a …
Published on:
INQ00015203_Approved Document L1A - Conservation of fuel and power - 2013 edition.pdf [pdf]
… INQ00015203_Approved Document L1A - Conservation of fuel and power - 2013 … use the specific fuel factor. For an appliance that is classed as mult i-fuel and that is not in a dwelling in a … of buildings containing more than one dwelling are not classified as dwellings and therefore fall outside the scope …
Published on:
BRE00027419_BRE and NHBC Fire performance of new residential buildings_4.pdf [pdf]
… BRE00027419_BRE and NHBC Fire performance of new residential buildings_4.pdf BRE00027419_BRE … the form d construction For more general information on the classification of modern forms of construction, the reader … studies related to modern forms d construction have adopted classifications related either to whether the system or …
Published on:
BRE00027419_BRE and NHBC Fire performance of new residential buildings_3.pdf [pdf]
… BRE00027419_BRE and NHBC Fire performance of new residential buildings_3.pdf BRE00027419_BRE … the form d construction For more general information on the classification of modern forms of construction, the reader … studies related to modern forms d construction have adopted classifications related either to whether the system or …
Published on: